Files
stack/agents/magica/work/queue-329/gate/cli-case2-unit.test.txt

60 lines
4.9 KiB
Plaintext
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
command: ["node", "--test", "/home/jwoltje/.t3/worktrees/mosaic-stack/magica-row329/packages/cli/tests/case2-unit.test.mjs"]
TMPDIR: /mnt/storage/scratch/tmp/qMUByD
begin: {"utc": "2026-10-24T20:17:44.557+00:00", "load1": "4.78"}
launch nice: 19
✔ row253 factory socket uses actual config and target-uid query without widening hardening (289.116013ms)
✔ row253 installer refuses unsafe location and query facts before unit writes (2868.134188ms)
✔ row253 query timeout kills its process group and leaves no running child (7051.851198ms)
✔ row253 protected homes refuse before any filesystem access (10.004732ms)
✔ row253 C4 sleep query has exact inner reason and cleans all members (10632.148103ms)
✔ row253 C4 signals query has exact inner reason and cleans all members (10614.56629ms)
✔ row253 C4 member query has exact inner reason and cleans all members (10610.298124ms)
✔ row253 C4 overflow is output-limit in both sudo modes (429.894317ms)
✔ row253 C4 stalled supervisor uses the outer reason and explicit residual cleanup (14135.845582ms)
✔ row253 C4 inline supervisor is byte-identical in both host scripts (0.352489ms)
✔ row253 C4 cleanup budget starts after inventory pass one (32.747187ms)
✔ row253 query reaps its group even when a child closes stdout before the query returns (135.960183ms)
✔ row253 config parser is strict (9.139818ms)
✔ a clean library render writes both units 0644 with the fixed lines, and enables both then starts the bus then the Console (98.708094ms)
✔ PATH starts with the --node directory, for a node outside the default list and for /usr/bin/node (108.45039ms)
✔ a failed bus start refuses with the Console not started (97.715171ms)
✔ the script never links a unit file (0.152558ms)
✔ factory renders --pm once and one MOSAIC_CLAUDE_BIN line, and without them both tokens render empty (547.22684ms)
✔ a re-install over running units says they are still on the old copy and must restart together, never that it started them (470.414221ms)
✔ a re-install to another copy re-renders both units, and an edited installed unit refuses (1045.624381ms)
✔ a template with a namespace, user or system call restriction refuses (271.540459ms)
✔ the bus template's EnvironmentFile line must be there and point at the session env, and the Console template must have none (188.520374ms)
✔ a template holding an unknown token, PermissionsStartOnly or a privileged Exec prefix refuses (142.322165ms)
✔ a symlink at either unit path refuses (172.220721ms)
✔ a --node that is relative, not root-owned or under <home> refuses (19.226904ms)
✔ a re-install with a different --node or different serve flags refuses (474.95285ms)
✔ an installed pair whose units name different copies refuses (258.29889ms)
✔ a copy id that is short, uppercase, holds / or .., or names no directory refuses (27.750058ms)
✔ library refuses a privileged-floor miss, a bad proof pair and every flag outside its set (276.607519ms)
✔ library refuses a proof file not owned by <user>'s uid (16.596055ms)
✔ factory refuses duplicate socket, a missing --port or --business, and each proxy flag (187.320193ms)
✔ row253 factory refuses retired TCP and a value after the socket marker (28.164164ms)
✔ factory refuses a --claude that is relative, not root-owned or under <home>, and a re-install with another --pm or --claude (1177.420722ms)
✔ the precheck passes on a good host and prints free memory, without the key (166.852043ms)
✔ the precheck refuses each failed host check (1355.880342ms)
✔ the precheck refuses a user missing from passwd, a business file that does not load, and a symlinked run root (758.701299ms)
✔ a bwrap that fails refuses and prints the sysctl and where bwrap is (158.296468ms)
✔ an unprivileged port floor at or below the Console's port refuses, and so does a missing Console unit (796.490867ms)
✔ bus.tester: library refuses it on, factory needs it on, and factory refuses a library business (707.986749ms)
✔ the claude check runs only for a claude-code instance, and refuses a claude that appends or answers wrong (1291.749168ms)
✔ the claude check runs the bus unit's MOSAIC_CLAUDE_BIN over claude on PATH (411.263611ms)
✔ the session env file refuses when missing, open to others, a symlink, empty, or emptied by a later line (1015.74608ms)
✔ inside a session's sandbox a bind below 1024 fails with EACCES, and a bind on a free high port succeeds (92.272439ms)
✔ Vikunja 614 factory: scoped @anthropic-ai Claude path renders and passes installed read-back (762.290157ms)
✔ Vikunja 614 factory: plain paths still refuse every named unsafe character (93.447741ms)
✔ Vikunja 614 precheck: explicit null and named notifier decisions pass (321.847088ms)
✔ Vikunja 614 precheck: notifier config refuses missing, public, malformed and extra-key decisions (1456.667519ms)
ℹ tests 47
ℹ suites 0
ℹ pass 47
ℹ fail 0
ℹ cancelled 0
ℹ skipped 0
ℹ todo 0
ℹ duration_ms 71963.003764