Mos relayed Jason's answers in mos-0787. P19 332: a CLI command and a
Console view for role-instance changes, held until Jason confirms Mos's
reading. P19 333: accepted as a documented limit, so the I6 brief and the
design's limits line now say I6 writes it as a known limit.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Answers Darkwing's round 6 review (28884) and Filbert's doc-only
follow-up (28883).
- After docker stop, the rule waits for "no such container" by id,
bounded by the core stop timeout, then rm -f and the same wait; a
container still there refuses exit 1, which the unit retries.
- A name conflict is now only a hand-made container without the store's
labels; it stays exit 3, which the unit does not retry.
- Start order: host.lock, store path, rootless check, leftover rule,
docker run.
- I6 gains two tests: run straight after a stop boots, and a leftover
never removed refuses exit 1.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Answers Darkwing's round 5 review (28880) and Filbert's doc-only
follow-ups (28881).
- connected follows the channel from the wrapper's creation, as a forked
child's does; the entry starts the broker on boot and the notifier on
start, so host.mjs:217 and :244 never wait on a pid line.
- Bus start makes <dataRoot>/bus at 0700 and takes its real path; the
bind source, mosaic.store label, leftover filter and hostStatus all use
it.
- A name conflict refuses with exit 3, names the container and the
client's exit code, gives host.lock back, and removes nothing.
- The host.pids test list names what each test does with the pid.
- I6 gains four lifecycle tests for these.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Answers Darkwing's round 4 review (comment 28877) and Filbert's
doc-only follow-up (28876).
- P: the core container's name is mosaic-core-<16 hex of SHA-256 of the
real path of <dataRoot>/bus>, keyed on the store like writer.lock, so
two data roots with the same business don't collide.
- Q: close() waits CLOSE_TIMEOUT_MS twice (host.mjs:30, 343, 347). The
host passes MOSAIC_CLOSE_TIMEOUT_MS to the entry; the core stop
timeout is two close timeouts plus 5 s (45 s today), used by the
leftover rule's docker stop -t.
- R: {from, pid} start line; connected turns false on the exit line,
client stdout close or exit, or a failed stdin write; host.pids is
null for both forks in containerized mode and adds container; the
pid-signalling host tests stay local, I6 uses docker exec kill.
- Nit: firstReply (129) and ended (148) cited apart from watchChildren
(159-165).
- I6 tests and design section 9 add the slow-notifier leftover, two data
roots, the missing-timeout refusal and connected.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Design section 3 gains "The core container's lifecycle": the fixed name,
labels and --rm; tagged fork lines that carry each fork's replies, kills
and exit codes, so the host's per-child stop, start-failure kill and
watchChildren keep their logic; what the entry does when one fork exits;
the client ending first; SIGTERM; the host dying without closing stdin
(not spiked, I6 measures it); the leftover removal at bus start; and
bus status liveness from the engine instead of the lock's container pid.
B2 now names caps on the entry's engine-relayed stdout. Section 9 and
I6's files and tests carry the new rules. Broker cites move to
0f3eb25ea after row 143; LAUNCH_OPS is process.mjs:5-20.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Darkwing L (comment 28863): section 3 gains "The host channel, a
boundary change". The bus host starts the core container with
`docker run -i` as its own child; core-entry.mjs forks process.mjs and
notifier-process.mjs with IPC inside it and relays tagged JSON lines over
the client's stdin and stdout. The core container runs with
--log-driver none, since replies carry caps; I6 tests that. The channel
adds no authentication of its own, so it is boundary change B2.
Darkwing M: the registry keeps the docker run client's pid and
startTime, so bindLaunch, runtime.mjs and broker.mjs are unchanged and
I5 changes no file in packages/bus. The human proof's ancestry check
never meets the client, so the mount list carries that boundary and I5
tests that a session can't reach sock/human or sock/relay. recover()
removes the container, kills a leftover client and binds as today.
Darkwing nits: the start check's temp names are patterns from their
writers, five state files, and the git-socket.mjs split across I3, I5
and I6.
Filbert (comment 28864): section 10 states the Console's outbound
reach on the mosaic-console bridge, no wider than today, with the
--network none forwarder as the not-spiked follow-up named on P19 333.
Section 7 says four networks and lists mosaic-console.
Section 11 lists B1 (the Console bind, before I4) and B2 (the host
channel, before I6); I4's and I6's gates name their ruling.
Doc-only: no test reads either file.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
The Console binds 0.0.0.0 in its own namespace behind a host-loopback
publish (a decision 107 enforcement change, reach unchanged). It mounts
businesses/ and its other mounts at their host paths, checks bus-host/
against an allowlist, turns the queue panel off, and answers 404 on every
board route. The git socket's bundles and land logs move to git-host/.
recover() still ends leftover runs host-lost. RESOLVED_VIA gets a
human-socket entry, and every container kind gets mount-list and
hardening tests. Spike citations are corrected, and the root case and
two-network setup are marked as not spiked.
Co-Authored-By: Claude Opus 5.5 <[email protected]>
Row 87, the I1 design. The design turns decisions 105 to 108 into
interfaces: one rootless endpoint named on every call, three images,
two broker listeners with a human-socket via value, a host relay with a
peer-pid check, sessions as hardened containers, file-held tokens,
egress only through an allowlist proxy, and the Console in a container
on the human socket. Every container claim cites spikes S0 to S9 or HP.
Mos ruled on the host-process reading (mos-0657): routes open to a
process under Jason's uid are decision 105's accepted limit; the
other-uid reach to the Console port goes to Jason as P19 333, default a
documented limit, and only I6's limits section waits on it.
The rows file holds the I2 to I6 briefs on the template, each with
owner, reviewers, files, what ships and gate. Doc-only: no test reads
either file.
Co-Authored-By: Claude Opus 5.5 <[email protected]>